title: "Signature Pad Configuration"
canonical: "https://kb.myframeworks.com.au/space/FRAM/28402510/Signature%20Pad%20Configuration"
format: markdown
---
The main moving parts of the Signature Pad device include:

# Windows PC

Windows PC at Point of Sales has two pieces of software installed:

- Java socket listener runs on windows, manages communication to device, listens on socket port 3333 for connection from Frameworks.
- Device driver software which talks directly to the signature pad.

The Windows PC has a mapped drive to the Frameworks Linux server /prostix/dmp/sig/ in order to send the saved .jpg signature files when captured at POS.

# Frameworks Configuration

1. Click **Frameworks **then navigate to **System Administration** > **Devices & Printing **> **Device Maintenance **from the navigation tree.
2. Ensure the Sigpad type and Sigpad Port numbers for each device using a signature pad at POS:
  - Sigpad Type = epadink
  - Sigpad Port = 3333
3. Within System Administration - Miscellaneous Table Maintenance - System Settings - General, the following tailoring options are configured:

| **Code** | **Setting Purpose** | **Value** |
| --- | --- | --- |
| *JobSubmPth* | Directory for Spool printing scripts | /prostix/bat  
** needs to be the same filepath as the location of the nuvusubm |
| *SigPathClt* | Signature Path on Client | v:\sig\ |
| *SigPathNv* | Signature Path on NuVu Server | c:\temp\ |
| *SigPathSvr* | Signature Path on Server | /prostix/dmp/sig/ |

> ⚠️ The above values are the standard default configuration, individual sites may vary.